title: "Distribution Switchboard / Panelboard | Entogo"
description: "A low-voltage distribution switchboard / panelboard for ≤600 V, 60 Hz power and lighting distribution — wall- or floor-mounted, with main and branch…"
url: https://entogo.ca/products/distribution-switchboard-panelboard/
lang: en
type: website
image: https://entogo.ca/_astro/Entogo-XL21-Low-Voltage-Power-Distribution-Cabinet.DSyEP0Ga.png
alternates:
  en: https://entogo.ca/products/distribution-switchboard-panelboard/
  fr-CA: https://entogo.ca/fr/products/distribution-switchboard-panelboard/
  es: https://entogo.ca/es/products/distribution-switchboard-panelboard/
  ar: https://entogo.ca/ar/products/distribution-switchboard-panelboard/
site: https://entogo.ca/
llms: https://entogo.ca/llms.txt
---

Home › Products › Switchgear & Distribution › Distribution Switchboard / Panelboard

Switchgear & Distribution

# Distribution Switchboard / Panelboard

≤ 600 V · panelboard & distribution

![Entogo low-voltage distribution switchboard and panelboard](https://entogo.ca/_astro/Entogo-XL21-Low-Voltage-Power-Distribution-Cabinet.DSyEP0Ga_Z2vFWJ3.webp)

Overview

A low-voltage distribution switchboard / panelboard for ≤600 V, 60 Hz power and lighting distribution — wall- or floor-mounted, with main and branch molded-case breakers, metering and SCCR to 100 kAIC. Designed to UL 67 (panelboard) and UL 891 (switchboard); UL/CSA certifiable.

Entogo designs and builds the Distribution Switchboard / Panelboard in its own factory with a vertically integrated supply chain: this product ships in 12–18 weeks (new UL or CSA certification can extend that, within a guaranteed 36-week worst case), and every Entogo product carries a minimum 36-month manufacturer warranty.

This **low-voltage distribution switchboard / panelboard** handles power and lighting distribution on **≤ 600 V**, 60 Hz systems — supplied as a **UL 67** panelboard for branch-circuit distribution up to about 1200 A, or as a **UL 891** distribution switchboard for larger feeder and service distribution from 800 to 6000 A. Main and branch molded-case breakers (UL 489) give flexible 3- and 4-wire configurations at **208Y/120 or 480Y/277 V**, with short-circuit ratings to **100 kAIC**.

Front-panel metering, indicators and control switches keep operation simple, in a compact, fully enclosed **NEMA 1** indoor or **3R** outdoor cabinet that wall- or floor-mounts in building electrical rooms. Designed and built to UL 67 / UL 891, with UL (cULus) / CSA certification available on request.

## Key features

- Power and lighting distribution for ≤ 600 V systems — panelboard (≤ 1200 A) or distribution switchboard (800 – 6000 A) per the load.
- Designed and built to UL 67 (panelboards) / UL 891 (switchboards), 60 Hz — UL (cULus) / CSA certification available on request.
- Main and branch molded-case breakers (UL 489); SCCR to 100 kAIC.
- Front-panel metering, indicators and controls; flexible 3- and 4-wire configurations.
- Compact, fully enclosed NEMA 1 indoor or 3R outdoor build; wall- or floor-mounted.

Custom-engineered · built to order

[Get a quote](https://entogo.ca/contact)

Lead time

12–18 weeks

Order now for estimated delivery Dec 2026 – Jan 2027.

Certification / testing may extend this per the standard and scope.

Quality & certifications

- ![UL safety certification mark](https://entogo.ca/_astro/Entogo-UL-Underwriters-Laboratories-North-America-Safety-Certification.BoQ45DeX_248O3C.webp)
- ![CSA certification mark](https://entogo.ca/_astro/Entogo-CSA-Canadian-Standards-Association-Safety-Certification.CY1FySDR_Z11vFCD.webp)
- ![CE European Conformity marking](https://entogo.ca/_astro/Entogo-CE-European-Conformity-Marking.xJPMJKcl_1wU1NT.webp)
- ![ISO 9001 quality management mark](https://entogo.ca/_astro/Entogo-ISO-9001-Quality-Management-System-Certification.DbscJvvM_47kvy.webp)
- ![ISO 14001 environmental management mark](https://entogo.ca/_astro/Entogo-ISO-14001-Environmental-Management-System-Certification.DXOTPjd4_Z4rpDm.webp)
- ![IEC CB Scheme mark](https://entogo.ca/_astro/Entogo-CB-Scheme-IEC-International-Electrical-Certification.CPXJ4xZK_aV0YT.webp)

Built under audited ISO quality systems and to ANSI/IEEE & IEC standards. Product-level UL (cULus) / CSA certification available on request.

[See all certifications](https://entogo.ca/certifications)

## Specifications

Distribution Switchboard / Panelboard specifications
| Specification | Value |
| --- | --- |
| Applicable standards | UL 67 (panelboards) / UL 891 (switchboards) · breakers UL 489 |
| Type | Distribution panelboard (≤ 1200 A) or switchboard (800 – 6000 A) |
| Rated voltage | ≤ 600 V |
| Systems | 3-phase 3-, 4-wire (208Y/120, 480Y/277) |
| Short-circuit / SCCR | Up to 65 – 100 kAIC |
| Frequency | 60 Hz |
| Overcurrent | Main + branch molded-case breakers (UL 489) |
| Metering | Front-panel instruments / digital meter optional |
| Enclosure | NEMA Type 1 (indoor) / 3R (outdoor); wall- or floor-mount |

Glossary: [Switchboard](https://entogo.ca/glossary#switchboard-ul-891) [Panelboard](https://entogo.ca/glossary#panelboard-ul-67) [60 Hz vs. 50 Hz](https://entogo.ca/glossary#60-hz-vs-50-hz)

## Applications

- Commercial and institutional power and lighting distribution
- Industrial and process-plant branch distribution
- Building feeder and sub-distribution panels
- Tenant and floor-level distribution

Payment & financing

Flexible payment and project financing is available for qualified projects — milestone-based plans, reduced upfront terms and third-party financing. Entogo is the equipment supplier, not a lender; all options are subject to credit review and a signed agreement.

[See payment options](https://entogo.ca/payment-options)

After-sales

Backed by Entogo lifecycle service — technical support, spare parts and a minimum 36-month warranty (well beyond the industry norm; up to 10 years on major power equipment, confirmed per contract). Our team responds to every request within one business day.

[After-sales support](https://entogo.ca/support) [Track an order](https://entogo.ca/support/order-status)

FAQ

## Common questions

- **Is this a panelboard or a switchboard?**: Either, depending on size. Branch-circuit distribution up to ~1200 A is built as a UL 67 panelboard; larger feeder and service distribution (800 – 6000 A) is built as a UL 891 switchboard. Both are ≤ 600 V, 60 Hz.
- **What systems and ratings are supported?**: 3-phase 3- and 4-wire at 208Y/120 or 480Y/277 V, ≤ 600 V, with SCCR to 100 kAIC and molded-case branch protection (UL 489), 60 Hz. UL (cULus) / CSA certification available on request.

Distribution

## Related products

[![Entogo metal-clad medium-voltage switchgear with drawout vacuum circuit breakers](https://entogo.ca/_astro/Entogo-Armored-Removable-AC-Metal-Enclosed-Switchgear.DuhYnxGM_1rPQtT.webp) Distribution ### Metal-Clad Switchgear (Drawout MV) Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable. View](https://entogo.ca/products/metal-clad-switchgear)[![Entogo dead-front low-voltage switchboard, UL 891 type](https://entogo.ca/_astro/Entogo-GGD-AC-Low-Voltage-Switchgear.zdOCIT9Q_6cFiL.webp) Distribution ### Low-Voltage Switchboard (UL 891) A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable. View](https://entogo.ca/products/low-voltage-switchboard)[![Entogo pad-mounted ring main unit load-break switchgear, dead-front](https://entogo.ca/_astro/Entogo-Gas-Fully-Insulated-Fully-Sealed-Ring-Main-Unit.BUgYaOBQ_1CzHVw.webp) Distribution ### Pad-Mounted Switchgear (Ring Main Unit) Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable. View](https://entogo.ca/products/pad-mounted-switchgear-rmu)

Request a quote

## Talk to engineering about the Distribution Switchboard / Panelboard.

[Start an inquiry](https://entogo.ca/contact)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/distribution-switchboard-panelboard/#product","url":"https://entogo.ca/products/distribution-switchboard-panelboard/","name":"Distribution Switchboard / Panelboard","description":"A low-voltage distribution switchboard / panelboard for ≤600 V, 60 Hz power and lighting distribution — wall- or floor-mounted, with main and branch molded-case breakers, metering and SCCR to 100 kAIC. Designed to UL 67 (panelboard) and UL 891 (switchboard); UL/CSA certifiable.","image":"https://entogo.ca/_astro/Entogo-XL21-Low-Voltage-Power-Distribution-Cabinet.DSyEP0Ga.png","category":"Switchgear & Distribution","additionalType":"https://en.wikipedia.org/wiki/Switchgear","brand":{"@type":"Brand","name":"Entogo"},"manufacturer":{"@id":"https://entogo.ca/#organization"},"model":"≤ 600 V · panelboard & distribution","additionalProperty":[{"@type":"PropertyValue","name":"Applicable standards","value":"UL 67 (panelboards) / UL 891 (switchboards) · breakers UL 489"},{"@type":"PropertyValue","name":"Type","value":"Distribution panelboard (≤ 1200 A) or switchboard (800 – 6000 A)"},{"@type":"PropertyValue","name":"Rated voltage","value":"≤ 600 V"},{"@type":"PropertyValue","name":"Systems","value":"3-phase 3-, 4-wire (208Y/120, 480Y/277)"},{"@type":"PropertyValue","name":"Short-circuit / SCCR","value":"Up to 65 – 100 kAIC"},{"@type":"PropertyValue","name":"Frequency","value":"60 Hz"},{"@type":"PropertyValue","name":"Overcurrent","value":"Main + branch molded-case breakers (UL 489)"},{"@type":"PropertyValue","name":"Metering","value":"Front-panel instruments / digital meter optional"},{"@type":"PropertyValue","name":"Enclosure","value":"NEMA Type 1 (indoor) / 3R (outdoor); wall- or floor-mount"},{"@type":"PropertyValue","name":"Application","value":"Commercial and institutional power and lighting distribution"},{"@type":"PropertyValue","name":"Application","value":"Industrial and process-plant branch distribution"},{"@type":"PropertyValue","name":"Application","value":"Building feeder and sub-distribution panels"},{"@type":"PropertyValue","name":"Application","value":"Tenant and floor-level distribution"},{"@type":"PropertyValue","name":"Delivery lead time","minValue":12,"maxValue":18,"unitCode":"WEE"},{"@type":"PropertyValue","name":"Warranty (minimum)","value":36,"unitCode":"MON"}],"isRelatedTo":[{"@type":"Product","name":"Metal-Clad Switchgear (Drawout MV)","url":"https://entogo.ca/products/metal-clad-switchgear/"},{"@type":"Product","name":"Low-Voltage Switchboard (UL 891)","url":"https://entogo.ca/products/low-voltage-switchboard/"},{"@type":"Product","name":"Pad-Mounted Switchgear (Ring Main Unit)","url":"https://entogo.ca/products/pad-mounted-switchgear-rmu/"}],"potentialAction":{"@type":"QuoteAction","name":"Request a quote","target":"https://entogo.ca/contact/"}}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://entogo.ca/"},{"@type":"ListItem","position":2,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":3,"name":"Switchgear & Distribution","item":"https://entogo.ca/products/category/switchgear-distribution/"},{"@type":"ListItem","position":4,"name":"Distribution Switchboard / Panelboard","item":"https://entogo.ca/products/distribution-switchboard-panelboard/"}]}
```

```json
{"@context":"https://schema.org","@type":"FAQPage","mainEntity":[{"@type":"Question","name":"Is this a panelboard or a switchboard?","acceptedAnswer":{"@type":"Answer","text":"Either, depending on size. Branch-circuit distribution up to ~1200 A is built as a UL 67 panelboard; larger feeder and service distribution (800 – 6000 A) is built as a UL 891 switchboard. Both are ≤ 600 V, 60 Hz."}},{"@type":"Question","name":"What systems and ratings are supported?","acceptedAnswer":{"@type":"Answer","text":"3-phase 3- and 4-wire at 208Y/120 or 480Y/277 V, ≤ 600 V, with SCCR to 100 kAIC and molded-case branch protection (UL 489), 60 Hz. UL (cULus) / CSA certification available on request."}}]}
```

_Markdown twin of https://entogo.ca/products/distribution-switchboard-panelboard/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_