# Low-Voltage Switchboard (UL 891)

≤ 600 V · up to 6000 A

![Entogo dead-front low-voltage switchboard, UL 891 type](https://entogo.ca/_astro/Entogo-GGD-AC-Low-Voltage-Switchgear.zdOCIT9Q_6cFiL.webp)

Overview

A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable.

Entogo designs and builds the Low-Voltage Switchboard (UL 891) in its own factory with a vertically integrated supply chain: this product ships in 12–18 weeks (new UL or CSA certification can extend that, within a guaranteed 36-week worst case), and every Entogo product carries a minimum 36-month manufacturer warranty.

This **dead-front low-voltage switchboard** handles service-entrance and feeder distribution on **≤ 600 V**, 60 Hz systems, with bus ratings from **800 to 6000 A** and short-circuit ratings to 200 kA. Group-mounted molded-case or insulated-case breakers give a flexible, sectionalized layout, and a service-entrance-rated configuration with metering provisions handles the utility tie-in for commercial, institutional and industrial buildings.

It offers high breaking capacity, good dynamic and thermal stability and a compact structure that fits building electrical rooms, in NEMA 1 indoor or 3R outdoor enclosures. Designed and built to **UL 891** with molded-case breakers to UL 489, and UL (cULus) / CSA certification available on request.

## Key features

- Dead-front switchboard for service-entrance and feeder distribution, designed and built to UL 891, 60 Hz — UL (cULus) / CSA certification available on request.
- 800 – 6000 A bus with short-circuit ratings to 200 kA and good dynamic / thermal stability.
- Group-mounted molded-case or insulated-case breakers; flexible, sectionalized layout.
- Service-entrance-rated configuration with metering provisions for utility tie-in.
- NEMA 1 indoor or 3R outdoor enclosure; compact structure sized for building electrical rooms.

Custom-engineered · built to order

[Get a quote](https://entogo.ca/contact/)

Lead time

12–18 weeks

Order now for estimated delivery Dec 2026 – Jan 2027.

Certification / testing may extend this per the standard and scope.

Quality & certifications

- ![UL safety certification mark](https://entogo.ca/_astro/Entogo-UL-Underwriters-Laboratories-North-America-Safety-Certification.BoQ45DeX_248O3C.webp)
- ![CSA certification mark](https://entogo.ca/_astro/Entogo-CSA-Canadian-Standards-Association-Safety-Certification.CY1FySDR_Z11vFCD.webp)
- ![CE European Conformity marking](https://entogo.ca/_astro/Entogo-CE-European-Conformity-Marking.xJPMJKcl_1wU1NT.webp)
- ![ISO 9001 quality management mark](https://entogo.ca/_astro/Entogo-ISO-9001-Quality-Management-System-Certification.DbscJvvM_47kvy.webp)
- ![ISO 14001 environmental management mark](https://entogo.ca/_astro/Entogo-ISO-14001-Environmental-Management-System-Certification.DXOTPjd4_Z4rpDm.webp)
- ![IEC CB Scheme mark](https://entogo.ca/_astro/Entogo-CB-Scheme-IEC-International-Electrical-Certification.CPXJ4xZK_aV0YT.webp)

Built under audited ISO quality systems and to ANSI/IEEE & IEC standards. Product-level UL (cULus) / CSA certification available on request.

[See all certifications](https://entogo.ca/certifications/)

## Specifications

Low-Voltage Switchboard (UL 891) specifications
| Specification | Value |
| --- | --- |
| Applicable standards | UL 891 (switchboards) · NEC service-entrance · breakers UL 489 |
| Type | Dead-front low-voltage switchboard (group- or individually-mounted) |
| Rated voltage | ≤ 600 V AC |
| Main bus / continuous | 800 – 6000 A |
| Short-circuit | Up to 200 kA, 3-cycle |
| Frequency | 60 Hz |
| Service entrance | Service-entrance rated option |
| Overcurrent | Molded-case (UL 489) or insulated-case breakers |
| Enclosure | NEMA Type 1 (indoor) / 3R (outdoor) |

Glossary: [Dead-front vs. live-front](https://entogo.ca/glossary/#dead-front-live-front) [Switchboard](https://entogo.ca/glossary/#switchboard-ul-891) [60 Hz vs. 50 Hz](https://entogo.ca/glossary/#60-hz-vs-50-hz)

## Applications

- Commercial and institutional service entrance and distribution
- Industrial and manufacturing plant distribution
- Data-center and mission-critical low-voltage distribution
- Power-plant and substation auxiliary power

Payment & financing

Flexible payment and project financing is available for qualified projects — milestone-based plans, reduced upfront terms and third-party financing. Entogo is the equipment supplier, not a lender; all options are subject to credit review and a signed agreement.

[See payment options](https://entogo.ca/payment-options/)

After-sales

Backed by Entogo lifecycle service — technical support, spare parts and a minimum 36-month warranty (well beyond the industry norm; up to 10 years on major power equipment, confirmed per contract). Our team responds to every request within one business day.

[After-sales support](https://entogo.ca/support/) [Track an order](https://entogo.ca/support/order-status/)

FAQ

## Common questions

- **What is the difference between a switchboard and switchgear?**: A UL 891 switchboard uses group- or individually-mounted molded-case / insulated-case breakers and is typically front-accessible — ideal for service entrance and building distribution. Drawout UL 1558 switchgear is a higher tier for mission-critical systems needing 30-cycle withstand and withdrawable breakers.
- **What ratings and standards apply?**: ≤ 600 V, 800 – 6000 A, up to 200 kA short-circuit, 60 Hz, with a service-entrance-rated option. Designed to UL 891; UL (cULus) / CSA certification available on request.

Distribution

## Related products

[![Entogo metal-clad medium-voltage switchgear with drawout vacuum circuit breakers](https://entogo.ca/_astro/Entogo-Armored-Removable-AC-Metal-Enclosed-Switchgear.DuhYnxGM_1rPQtT.webp) Distribution ### Metal-Clad Switchgear (Drawout MV) Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable. View](https://entogo.ca/products/metal-clad-switchgear/)[![Entogo pad-mounted ring main unit load-break switchgear, dead-front](https://entogo.ca/_astro/Entogo-Gas-Fully-Insulated-Fully-Sealed-Ring-Main-Unit.BUgYaOBQ_1CzHVw.webp) Distribution ### Pad-Mounted Switchgear (Ring Main Unit) Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable. View](https://entogo.ca/products/pad-mounted-switchgear-rmu/)[![Entogo metal-enclosed load-interrupter medium-voltage switchgear](https://entogo.ca/_astro/Entogo-Box-Type-Fixed-Metal-Enclosed-Switchgear.Cc7QCP4l_1y87ft.webp) Distribution ### Metal-Enclosed Load-Interrupter Switchgear Metal-enclosed load-interrupter switchgear for 15 / 27 / 38 kV class medium-voltage systems, 60 Hz — fixed-mounted load-break switches with power-fuse protection in a compact steel enclosure, for compact substations, primary service entrance and MV isolation. Designed to ANSI/IEEE C37.20.3; UL / CSA certifiable. View](https://entogo.ca/products/metal-enclosed-switchgear/)

Request a quote

## Talk to engineering about the Low-Voltage Switchboard (UL 891).

[Start an inquiry](https://entogo.ca/contact/)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/low-voltage-switchboard/#product","url":"https://entogo.ca/products/low-voltage-switchboard/","name":"Low-Voltage Switchboard (UL 891)","description":"A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable.","image":"https://entogo.ca/_astro/Entogo-GGD-AC-Low-Voltage-Switchgear.zdOCIT9Q.png","category":"Switchgear & Distribution","additionalType":"https://en.wikipedia.org/wiki/Switchgear","brand":{"@type":"Brand","name":"Entogo"},"manufacturer":{"@id":"https://entogo.ca/#organization"},"model":"≤ 600 V · up to 6000 A","additionalProperty":[{"@type":"PropertyValue","name":"Applicable standards","value":"UL 891 (switchboards) · NEC service-entrance · breakers UL 489"},{"@type":"PropertyValue","name":"Type","value":"Dead-front low-voltage switchboard (group- or individually-mounted)"},{"@type":"PropertyValue","name":"Rated voltage","value":"≤ 600 V AC"},{"@type":"PropertyValue","name":"Main bus / continuous","value":"800 – 6000 A"},{"@type":"PropertyValue","name":"Short-circuit","value":"Up to 200 kA, 3-cycle"},{"@type":"PropertyValue","name":"Frequency","value":"60 Hz"},{"@type":"PropertyValue","name":"Service entrance","value":"Service-entrance rated option"},{"@type":"PropertyValue","name":"Overcurrent","value":"Molded-case (UL 489) or insulated-case breakers"},{"@type":"PropertyValue","name":"Enclosure","value":"NEMA Type 1 (indoor) / 3R (outdoor)"},{"@type":"PropertyValue","name":"Application","value":"Commercial and institutional service entrance and distribution"},{"@type":"PropertyValue","name":"Application","value":"Industrial and manufacturing plant distribution"},{"@type":"PropertyValue","name":"Application","value":"Data-center and mission-critical low-voltage distribution"},{"@type":"PropertyValue","name":"Application","value":"Power-plant and substation auxiliary power"},{"@type":"PropertyValue","name":"Delivery lead time","minValue":12,"maxValue":18,"unitCode":"WEE"},{"@type":"PropertyValue","name":"Warranty (minimum)","value":36,"unitCode":"MON"}],"isRelatedTo":[{"@type":"Product","name":"Metal-Clad Switchgear (Drawout MV)","url":"https://entogo.ca/products/metal-clad-switchgear/"},{"@type":"Product","name":"Pad-Mounted Switchgear (Ring Main Unit)","url":"https://entogo.ca/products/pad-mounted-switchgear-rmu/"},{"@type":"Product","name":"Metal-Enclosed Load-Interrupter Switchgear","url":"https://entogo.ca/products/metal-enclosed-switchgear/"}],"potentialAction":{"@type":"QuoteAction","name":"Request a quote","target":"https://entogo.ca/contact/"}}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://entogo.ca/"},{"@type":"ListItem","position":2,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":3,"name":"Switchgear & Distribution","item":"https://entogo.ca/products/category/switchgear-distribution/"},{"@type":"ListItem","position":4,"name":"Low-Voltage Switchboard (UL 891)","item":"https://entogo.ca/products/low-voltage-switchboard/"}]}
```

```json
{"@context":"https://schema.org","@type":"FAQPage","mainEntity":[{"@type":"Question","name":"What is the difference between a switchboard and switchgear?","acceptedAnswer":{"@type":"Answer","text":"A UL 891 switchboard uses group- or individually-mounted molded-case / insulated-case breakers and is typically front-accessible — ideal for service entrance and building distribution. Drawout UL 1558 switchgear is a higher tier for mission-critical systems needing 30-cycle withstand and withdrawable breakers."}},{"@type":"Question","name":"What ratings and standards apply?","acceptedAnswer":{"@type":"Answer","text":"≤ 600 V, 800 – 6000 A, up to 200 kA short-circuit, 60 Hz, with a service-entrance-rated option. Designed to UL 891; UL (cULus) / CSA certification available on request."}}]}
```

_Markdown twin of https://entogo.ca/products/low-voltage-switchboard/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_