Home › Products › Switchgear & Distribution › Modular Low-Voltage Switchgear / MCC

Switchgear & Distribution

# Modular Low-Voltage Switchgear / MCC

≤ 600 V · up to 5000 A · modular drawer

![Entogo modular drawer-type low-voltage switchgear and motor control center](https://entogo.ca/_astro/Entogo-MNS-Low-Voltage-Withdrawable-Switchgear.DJOoH7XN_Z26kTQH.webp)

Overview

Modular drawer-type low-voltage switchgear and motor control center for ≤600 V, 60 Hz three-phase systems — standardized, mechanically interlocked withdrawable drawers up to 5000 A and 100 kAIC. Designed to UL 1558 and UL 845; UL/CSA certifiable.

Entogo designs and builds the Modular Low-Voltage Switchgear / MCC in its own factory with a vertically integrated supply chain: this product ships in 12–18 weeks (new UL or CSA certification can extend that, within a guaranteed 36-week worst case), and every Entogo product carries a minimum 36-month manufacturer warranty.

This **modular low-voltage switchgear** and motor control center is assembled from standardized, mechanically interlocked withdrawable drawers, giving a high-density line-up that is quick to configure and safe to maintain. It serves **≤ 600 V**, 60 Hz three-phase, four-wire systems up to **5000 A**, with short-circuit ratings to **100 kAIC** for heavy distribution and motor-control duty.

The same drawer construction and interlocking serve power plants, substations, data centers, commercial buildings and transport hubs, in NEMA 1 indoor or 3R outdoor enclosures with optional metering and SCADA integration. Designed and built to **UL 1558** (low-voltage switchgear) and **UL 845** (motor control center), with UL (cULus) / CSA certification available on request.

## Key features

- Standardized, modular drawer construction with reliable mechanical interlocking for safe operation and fast reconfiguration.
- Designed and built to UL 1558 (switchgear) / UL 845 (MCC), 60 Hz — UL (cULus) / CSA certification available on request.
- Up to 600 V and 5000 A with 65 / 85 / 100 kAIC short-circuit ratings for heavy distribution and motor-control duty.
- High packing density and broad application across utility, industry, data center and infrastructure.
- NEMA 1 indoor or 3R outdoor enclosure; metering and SCADA integration optional.

Custom-engineered · built to order

[Get a quote](https://entogo.ca/contact/)

Lead time

12–18 weeks

Order now for estimated delivery Dec 2026 – Jan 2027.

Certification / testing may extend this per the standard and scope.

Quality & certifications

- ![UL safety certification mark](https://entogo.ca/_astro/Entogo-UL-Underwriters-Laboratories-North-America-Safety-Certification.BoQ45DeX_248O3C.webp)
- ![CSA certification mark](https://entogo.ca/_astro/Entogo-CSA-Canadian-Standards-Association-Safety-Certification.CY1FySDR_Z11vFCD.webp)
- ![CE European Conformity marking](https://entogo.ca/_astro/Entogo-CE-European-Conformity-Marking.xJPMJKcl_1wU1NT.webp)
- ![ISO 9001 quality management mark](https://entogo.ca/_astro/Entogo-ISO-9001-Quality-Management-System-Certification.DbscJvvM_47kvy.webp)
- ![ISO 14001 environmental management mark](https://entogo.ca/_astro/Entogo-ISO-14001-Environmental-Management-System-Certification.DXOTPjd4_Z4rpDm.webp)
- ![IEC CB Scheme mark](https://entogo.ca/_astro/Entogo-CB-Scheme-IEC-International-Electrical-Certification.CPXJ4xZK_aV0YT.webp)

Built under audited ISO quality systems and to ANSI/IEEE & IEC standards. Product-level UL (cULus) / CSA certification available on request.

[See all certifications](https://entogo.ca/certifications/)

## Specifications

Modular Low-Voltage Switchgear / MCC specifications
| Specification | Value |
| --- | --- |
| Applicable standards | UL 1558 · UL 845 (MCC) · ANSI/IEEE C37.20.1 · breakers UL 1066 / UL 489 |
| Type | Modular, drawer-type low-voltage switchgear / MCC |
| Rated voltage | ≤ 600 V |
| System | Three-phase, four-wire |
| Main bus / continuous | Up to 5000 A |
| Short-circuit / SCCR | 65 / 85 / 100 kAIC |
| Frequency | 60 Hz |
| Drawers | Standardized modules with mechanical interlocking |
| Enclosure | NEMA Type 1 (indoor) / 3R (outdoor) |

Glossary: [Low-voltage switchgear](https://entogo.ca/glossary/#low-voltage-switchgear-ul-1558) [Motor control center](https://entogo.ca/glossary/#motor-control-center) [60 Hz vs. 50 Hz](https://entogo.ca/glossary/#60-hz-vs-50-hz)

## Applications

- Power plants, substations and heavy industry
- Data-center and mission-critical low-voltage distribution
- Commercial buildings, hotels, airports and ports
- Communication and broadcast facilities

Payment & financing

Flexible payment and project financing is available for qualified projects — milestone-based plans, reduced upfront terms and third-party financing. Entogo is the equipment supplier, not a lender; all options are subject to credit review and a signed agreement.

[See payment options](https://entogo.ca/payment-options/)

After-sales

Backed by Entogo lifecycle service — technical support, spare parts and a minimum 36-month warranty (well beyond the industry norm; up to 10 years on major power equipment, confirmed per contract). Our team responds to every request within one business day.

[After-sales support](https://entogo.ca/support/) [Track an order](https://entogo.ca/support/order-status/)

FAQ

## Common questions

- **What makes this switchgear "modular"?**: It is built from standardized, mechanically interlocked withdrawable drawers, so feeder and motor-control units can be added, swapped or reconfigured quickly within a high-density line-up — the modular drawer approach to UL 1558 / UL 845 low-voltage gear.
- **What ratings and standards apply?**: ≤ 600 V, three-phase four-wire, up to 5000 A, 65 / 85 / 100 kAIC, 60 Hz. Designed to UL 1558 (switchgear) and UL 845 (MCC); UL (cULus) / CSA certification available on request.

Distribution

## Related products

[![Entogo metal-clad medium-voltage switchgear with drawout vacuum circuit breakers](https://entogo.ca/_astro/Entogo-Armored-Removable-AC-Metal-Enclosed-Switchgear.DuhYnxGM_1rPQtT.webp) Distribution ### Metal-Clad Switchgear (Drawout MV) Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable. View](https://entogo.ca/products/metal-clad-switchgear/)[![Entogo dead-front low-voltage switchboard, UL 891 type](https://entogo.ca/_astro/Entogo-GGD-AC-Low-Voltage-Switchgear.zdOCIT9Q_6cFiL.webp) Distribution ### Low-Voltage Switchboard (UL 891) A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable. View](https://entogo.ca/products/low-voltage-switchboard/)[![Entogo pad-mounted ring main unit load-break switchgear, dead-front](https://entogo.ca/_astro/Entogo-Gas-Fully-Insulated-Fully-Sealed-Ring-Main-Unit.BUgYaOBQ_1CzHVw.webp) Distribution ### Pad-Mounted Switchgear (Ring Main Unit) Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable. View](https://entogo.ca/products/pad-mounted-switchgear-rmu/)

Request a quote

## Talk to engineering about the Modular Low-Voltage Switchgear / MCC.

[Start an inquiry](https://entogo.ca/contact/)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/modular-low-voltage-switchgear/#product","url":"https://entogo.ca/products/modular-low-voltage-switchgear/","name":"Modular Low-Voltage Switchgear / MCC","description":"Modular drawer-type low-voltage switchgear and motor control center for ≤600 V, 60 Hz three-phase systems — standardized, mechanically interlocked withdrawable drawers up to 5000 A and 100 kAIC. Designed to UL 1558 and UL 845; UL/CSA certifiable.","image":"https://entogo.ca/_astro/Entogo-MNS-Low-Voltage-Withdrawable-Switchgear.DJOoH7XN.png","category":"Switchgear & Distribution","additionalType":"https://en.wikipedia.org/wiki/Switchgear","brand":{"@type":"Brand","name":"Entogo"},"manufacturer":{"@id":"https://entogo.ca/#organization"},"model":"≤ 600 V · up to 5000 A · modular drawer","additionalProperty":[{"@type":"PropertyValue","name":"Applicable standards","value":"UL 1558 · UL 845 (MCC) · ANSI/IEEE C37.20.1 · breakers UL 1066 / UL 489"},{"@type":"PropertyValue","name":"Type","value":"Modular, drawer-type low-voltage switchgear / MCC"},{"@type":"PropertyValue","name":"Rated voltage","value":"≤ 600 V"},{"@type":"PropertyValue","name":"System","value":"Three-phase, four-wire"},{"@type":"PropertyValue","name":"Main bus / continuous","value":"Up to 5000 A"},{"@type":"PropertyValue","name":"Short-circuit / SCCR","value":"65 / 85 / 100 kAIC"},{"@type":"PropertyValue","name":"Frequency","value":"60 Hz"},{"@type":"PropertyValue","name":"Drawers","value":"Standardized modules with mechanical interlocking"},{"@type":"PropertyValue","name":"Enclosure","value":"NEMA Type 1 (indoor) / 3R (outdoor)"},{"@type":"PropertyValue","name":"Application","value":"Power plants, substations and heavy industry"},{"@type":"PropertyValue","name":"Application","value":"Data-center and mission-critical low-voltage distribution"},{"@type":"PropertyValue","name":"Application","value":"Commercial buildings, hotels, airports and ports"},{"@type":"PropertyValue","name":"Application","value":"Communication and broadcast facilities"},{"@type":"PropertyValue","name":"Delivery lead time","minValue":12,"maxValue":18,"unitCode":"WEE"},{"@type":"PropertyValue","name":"Warranty (minimum)","value":36,"unitCode":"MON"}],"isRelatedTo":[{"@type":"Product","name":"Metal-Clad Switchgear (Drawout MV)","url":"https://entogo.ca/products/metal-clad-switchgear/"},{"@type":"Product","name":"Low-Voltage Switchboard (UL 891)","url":"https://entogo.ca/products/low-voltage-switchboard/"},{"@type":"Product","name":"Pad-Mounted Switchgear (Ring Main Unit)","url":"https://entogo.ca/products/pad-mounted-switchgear-rmu/"}],"potentialAction":{"@type":"QuoteAction","name":"Request a quote","target":"https://entogo.ca/contact/"}}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://entogo.ca/"},{"@type":"ListItem","position":2,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":3,"name":"Switchgear & Distribution","item":"https://entogo.ca/products/category/switchgear-distribution/"},{"@type":"ListItem","position":4,"name":"Modular Low-Voltage Switchgear / MCC","item":"https://entogo.ca/products/modular-low-voltage-switchgear/"}]}
```

```json
{"@context":"https://schema.org","@type":"FAQPage","mainEntity":[{"@type":"Question","name":"What makes this switchgear \"modular\"?","acceptedAnswer":{"@type":"Answer","text":"It is built from standardized, mechanically interlocked withdrawable drawers, so feeder and motor-control units can be added, swapped or reconfigured quickly within a high-density line-up — the modular drawer approach to UL 1558 / UL 845 low-voltage gear."}},{"@type":"Question","name":"What ratings and standards apply?","acceptedAnswer":{"@type":"Answer","text":"≤ 600 V, three-phase four-wire, up to 5000 A, 65 / 85 / 100 kAIC, 60 Hz. Designed to UL 1558 (switchgear) and UL 845 (MCC); UL (cULus) / CSA certification available on request."}}]}
```

_Markdown twin of https://entogo.ca/products/modular-low-voltage-switchgear/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_