title: "HLX New-Energy AC/DC Combiner Box | Entogo"
description: "The HLX combiner box for photovoltaic systems — the DC version consolidates up to 24 PV string inputs with per-string fuses, surge arresters and breakers;…"
url: https://entogo.ca/products/new-energy-ac-dc-combiner-box/
lang: en
type: website
image: https://entogo.ca/_astro/Entogo-New-Energy-AC-DC-Combiner-Box.nbhNagRI.png
alternates:
  en: https://entogo.ca/products/new-energy-ac-dc-combiner-box/
  fr-CA: https://entogo.ca/fr/products/new-energy-ac-dc-combiner-box/
  es: https://entogo.ca/es/products/new-energy-ac-dc-combiner-box/
  ar: https://entogo.ca/ar/products/new-energy-ac-dc-combiner-box/
site: https://entogo.ca/
llms: https://entogo.ca/llms.txt
---

Home › Products › Switchgear & Distribution › HLX New-Energy AC/DC Combiner Box

Switchgear & Distribution

# HLX New-Energy AC/DC Combiner Box

HLX · ≤24 strings · ≤AC 690 V

![Entogo HLX new-energy AC/DC combiner box for photovoltaic systems](https://entogo.ca/_astro/Entogo-New-Energy-AC-DC-Combiner-Box.nbhNagRI_ZXDBE8.webp)

Overview

The HLX combiner box for photovoltaic systems — the DC version consolidates up to 24 PV string inputs with per-string fuses, surge arresters and breakers; the AC version links string inverters to AC distribution at up to 690 V, IP65 for outdoor use.

Entogo designs and builds the HLX New-Energy AC/DC Combiner Box in its own factory with a vertically integrated supply chain: this product ships in 12–18 weeks (new UL or CSA certification can extend that, within a guaranteed 36-week worst case), and every Entogo product carries a minimum 36-month manufacturer warranty.

The HLX **combiner box** serves both sides of a PV array. The DC version gathers up to **24 string inputs** into one or more outputs, each protected by fuses with surge-arrester and breaker protection, simplifying wiring into DC cabinets and inverters. The AC version links string inverters to AC distribution or step-up transformers at up to **690 V**, in an **IP65** enclosure rated for outdoor weather, UV and salt-spray exposure.

## Key features

- DC version consolidates up to 24 PV strings into one or more outputs.
- Per-string fuses with surge-arrester and breaker output protection.
- AC version bridges string inverters to AC distribution or step-up transformers.
- IP65 enclosure for outdoor PV installations.

Custom-engineered · built to order

[Get a quote](https://entogo.ca/contact/)

Lead time

12–18 weeks

Order now for estimated delivery Dec 2026 – Jan 2027.

Certification / testing may extend this per the standard and scope.

Quality & certifications

- ![UL safety certification mark](https://entogo.ca/_astro/Entogo-UL-Underwriters-Laboratories-North-America-Safety-Certification.BoQ45DeX_248O3C.webp)
- ![CSA certification mark](https://entogo.ca/_astro/Entogo-CSA-Canadian-Standards-Association-Safety-Certification.CY1FySDR_Z11vFCD.webp)
- ![CE European Conformity marking](https://entogo.ca/_astro/Entogo-CE-European-Conformity-Marking.xJPMJKcl_1wU1NT.webp)
- ![ISO 9001 quality management mark](https://entogo.ca/_astro/Entogo-ISO-9001-Quality-Management-System-Certification.DbscJvvM_47kvy.webp)
- ![ISO 14001 environmental management mark](https://entogo.ca/_astro/Entogo-ISO-14001-Environmental-Management-System-Certification.DXOTPjd4_Z4rpDm.webp)
- ![IEC CB Scheme mark](https://entogo.ca/_astro/Entogo-CB-Scheme-IEC-International-Electrical-Certification.CPXJ4xZK_aV0YT.webp)

Built under audited ISO quality systems and to ANSI/IEEE & IEC standards. Product-level UL (cULus) / CSA certification available on request.

[See all certifications](https://entogo.ca/certifications/)

## Specifications

HLX New-Energy AC/DC Combiner Box specifications
| Specification | Value |
| --- | --- |
| Model | HLX |
| DC inputs | Up to 24 PV string circuits |
| DC protection | Per-string fuses + surge arrester + breaker |
| AC max voltage | 690 V |
| Protection rating | IP65 |
| Environment | Waterproof, dustproof, UV- and salt-spray-resistant |

Glossary: [Step-up](https://entogo.ca/glossary/#step-up-collector-transformer)

## Applications

- PV string power plants
- Inverter-to-distribution interface
- Outdoor solar installations

Payment & financing

Flexible payment and project financing is available for qualified projects — milestone-based plans, reduced upfront terms and third-party financing. Entogo is the equipment supplier, not a lender; all options are subject to credit review and a signed agreement.

[See payment options](https://entogo.ca/payment-options/)

After-sales

Backed by Entogo lifecycle service — technical support, spare parts and a minimum 36-month warranty (well beyond the industry norm; up to 10 years on major power equipment, confirmed per contract). Our team responds to every request within one business day.

[After-sales support](https://entogo.ca/support/) [Track an order](https://entogo.ca/support/order-status/)

Distribution

## Related products

[![Entogo metal-clad medium-voltage switchgear with drawout vacuum circuit breakers](https://entogo.ca/_astro/Entogo-Armored-Removable-AC-Metal-Enclosed-Switchgear.DuhYnxGM_1rPQtT.webp) Distribution ### Metal-Clad Switchgear (Drawout MV) Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable. View](https://entogo.ca/products/metal-clad-switchgear/)[![Entogo dead-front low-voltage switchboard, UL 891 type](https://entogo.ca/_astro/Entogo-GGD-AC-Low-Voltage-Switchgear.zdOCIT9Q_6cFiL.webp) Distribution ### Low-Voltage Switchboard (UL 891) A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable. View](https://entogo.ca/products/low-voltage-switchboard/)[![Entogo pad-mounted ring main unit load-break switchgear, dead-front](https://entogo.ca/_astro/Entogo-Gas-Fully-Insulated-Fully-Sealed-Ring-Main-Unit.BUgYaOBQ_1CzHVw.webp) Distribution ### Pad-Mounted Switchgear (Ring Main Unit) Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable. View](https://entogo.ca/products/pad-mounted-switchgear-rmu/)

Request a quote

## Talk to engineering about the HLX New-Energy AC/DC Combiner Box.

[Start an inquiry](https://entogo.ca/contact/)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/new-energy-ac-dc-combiner-box/#product","url":"https://entogo.ca/products/new-energy-ac-dc-combiner-box/","name":"HLX New-Energy AC/DC Combiner Box","description":"The HLX combiner box for photovoltaic systems — the DC version consolidates up to 24 PV string inputs with per-string fuses, surge arresters and breakers; the AC version links string inverters to AC distribution at up to 690 V, IP65 for outdoor use.","image":"https://entogo.ca/_astro/Entogo-New-Energy-AC-DC-Combiner-Box.nbhNagRI.png","category":"Switchgear & Distribution","additionalType":"https://en.wikipedia.org/wiki/Switchgear","brand":{"@type":"Brand","name":"Entogo"},"manufacturer":{"@id":"https://entogo.ca/#organization"},"model":"HLX · ≤24 strings · ≤AC 690 V","additionalProperty":[{"@type":"PropertyValue","name":"Model","value":"HLX"},{"@type":"PropertyValue","name":"DC inputs","value":"Up to 24 PV string circuits"},{"@type":"PropertyValue","name":"DC protection","value":"Per-string fuses + surge arrester + breaker"},{"@type":"PropertyValue","name":"AC max voltage","value":"690 V"},{"@type":"PropertyValue","name":"Protection rating","value":"IP65"},{"@type":"PropertyValue","name":"Environment","value":"Waterproof, dustproof, UV- and salt-spray-resistant"},{"@type":"PropertyValue","name":"Application","value":"PV string power plants"},{"@type":"PropertyValue","name":"Application","value":"Inverter-to-distribution interface"},{"@type":"PropertyValue","name":"Application","value":"Outdoor solar installations"},{"@type":"PropertyValue","name":"Delivery lead time","minValue":12,"maxValue":18,"unitCode":"WEE"},{"@type":"PropertyValue","name":"Warranty (minimum)","value":36,"unitCode":"MON"}],"isRelatedTo":[{"@type":"Product","name":"Metal-Clad Switchgear (Drawout MV)","url":"https://entogo.ca/products/metal-clad-switchgear/"},{"@type":"Product","name":"Low-Voltage Switchboard (UL 891)","url":"https://entogo.ca/products/low-voltage-switchboard/"},{"@type":"Product","name":"Pad-Mounted Switchgear (Ring Main Unit)","url":"https://entogo.ca/products/pad-mounted-switchgear-rmu/"}],"potentialAction":{"@type":"QuoteAction","name":"Request a quote","target":"https://entogo.ca/contact/"}}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://entogo.ca/"},{"@type":"ListItem","position":2,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":3,"name":"Switchgear & Distribution","item":"https://entogo.ca/products/category/switchgear-distribution/"},{"@type":"ListItem","position":4,"name":"HLX New-Energy AC/DC Combiner Box","item":"https://entogo.ca/products/new-energy-ac-dc-combiner-box/"}]}
```

_Markdown twin of https://entogo.ca/products/new-energy-ac-dc-combiner-box/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_