---
title: "36 kV Oil-Immersed Power Transformer | Entogo"
description: "A liquid-filled (mineral oil) three-phase power transformer for substation and subtransmission duty in 34.5 / 35 / 36 kV networks, rated 2.5 to 31.5 MVA…"
url: https://entogo.ca/products/oil-immersed-power-transformer-36kv/
lang: en
type: website
image: https://entogo.ca/_astro/Entogo-35kV-Three-Phase-Oil-Immersed-Distribution-Transformer.BWoRk9EQ.png
alternates:
  en: https://entogo.ca/products/oil-immersed-power-transformer-36kv/
  fr-CA: https://entogo.ca/fr/products/oil-immersed-power-transformer-36kv/
  es: https://entogo.ca/es/products/oil-immersed-power-transformer-36kv/
  ar: https://entogo.ca/ar/products/oil-immersed-power-transformer-36kv/
site: https://entogo.ca/
llms: https://entogo.ca/llms.txt
---

Home › Products › Transformers & Substations › 36 kV Oil-Immersed Power Transformer

Transformers & Substations

# 36 kV Oil-Immersed Power Transformer

2.5 – 31.5 MVA · 36 kV class

Configure & quote

## Customize your 36 kV Oil-Immersed Power Transformer and get a quote.

[Configure & get a quote](https://entogo.ca/products/transformer-quote?from=36%20kV%20Oil-Immersed%20Power%20Transformer)

![Entogo 36 kV class three-phase oil-immersed power transformer for substations](https://entogo.ca/_astro/Entogo-35kV-Three-Phase-Oil-Immersed-Distribution-Transformer.BWoRk9EQ_Z1dAjmQ.webp)

Overview

A liquid-filled (mineral oil) three-phase power transformer for substation and subtransmission duty in 34.5 / 35 / 36 kV networks, rated 2.5 to 31.5 MVA with ONAN / ONAF cooling, off-circuit or on-load tap changing and copper windings, designed to IEEE C57.12.00 / C57.12.10 and IEC 60076.

Entogo designs and builds the 36 kV Oil-Immersed Power Transformer in its own factory with a vertically integrated supply chain: this product ships in 16–24 weeks (new UL or CSA certification can extend that, within a guaranteed 36-week worst case), and every Entogo product carries a minimum 36-month manufacturer warranty.

Entogo’s **36 kV class oil-immersed power transformer** is a three-phase, liquid-filled unit built for substation and subtransmission service on 34.5 / 35 kV networks across North America, Europe and export markets. Ratings span **2.5 to 31.5 MVA** with ONAN / ONAN-ONAF cooling, copper windings on a CRGO silicon-steel core-form, and a full standards envelope covering **IEEE C57.12.00 / C57.12.10**, **IEC 60076** and CSA C88.

Mechanical and electrical configuration is specified per project — vector group, BIL, tap-changer type (**DETC** standard, **OLTC** optional with motor drive and AVR), bushing style, insulating liquid (mineral oil standard, FR3 natural ester for fire-safer urban siting) and accessory protection package (Buchholz, pressure-relief, oil-temperature and winding-temperature indicators). The result is a substation transformer that drops into utility, industrial and renewables interconnection assets without bespoke retrofit.

## Key features

- Designed to IEEE C57.12.00 / C57.12.10 and IEC 60076 — interchangeable with North American and European substation standards.
- Three-phase core-form construction with copper windings and CRGO silicon steel for low no-load loss.
- ONAN base rating with ONAF (forced-air) upgrade typically delivering +33 % continuous capacity.
- Hermetically sealed or conservator-tank construction; mineral oil with FR3 natural ester option for fire-safer indoor / urban siting.
- Off-circuit DETC standard; on-load tap changer with motor drive and AVR controller available.
- Full protection package — Buchholz / sudden-pressure relay, pressure-relief device, oil and winding-temperature indicators, dial gauges.
- Suitable for utility substations, industrial step-down, renewables interconnection and HVAC subtransmission.

Custom-engineered · built to order

[Get a quote](https://entogo.ca/products/transformer-quote?from=36%20kV%20Oil-Immersed%20Power%20Transformer)

Lead time

16–24 weeks

Order now for estimated delivery Jan 2027 – Mar 2027.

Certification / testing may extend this per the standard and scope.

Quality & certifications

- ![UL safety certification mark](https://entogo.ca/_astro/Entogo-UL-Underwriters-Laboratories-North-America-Safety-Certification.BoQ45DeX_248O3C.webp)
- ![CSA certification mark](https://entogo.ca/_astro/Entogo-CSA-Canadian-Standards-Association-Safety-Certification.CY1FySDR_Z11vFCD.webp)
- ![CE European Conformity marking](https://entogo.ca/_astro/Entogo-CE-European-Conformity-Marking.xJPMJKcl_1wU1NT.webp)
- ![ISO 9001 quality management mark](https://entogo.ca/_astro/Entogo-ISO-9001-Quality-Management-System-Certification.DbscJvvM_47kvy.webp)
- ![ISO 14001 environmental management mark](https://entogo.ca/_astro/Entogo-ISO-14001-Environmental-Management-System-Certification.DXOTPjd4_Z4rpDm.webp)
- ![IEC CB Scheme mark](https://entogo.ca/_astro/Entogo-CB-Scheme-IEC-International-Electrical-Certification.CPXJ4xZK_aV0YT.webp)

Built under audited ISO quality systems and to ANSI/IEEE & IEC standards. Product-level UL (cULus) / CSA certification available on request.

[See all certifications](https://entogo.ca/certifications)

## Specifications

36 kV Oil-Immersed Power Transformer specifications
| Specification | Value |
| --- | --- |
| Applicable standards | IEEE C57.12.00 / C57.12.10 · IEC 60076 · CSA C88 |
| Rated capacity | 2.5 – 31.5 MVA |
| Highest voltage for equipment (Um) | 36 kV class (system 34.5 / 35 kV) |
| Low-voltage winding | 0.4 / 4.16 / 6.6 / 12.47 / 13.8 kV (others on request) |
| Frequency | 50 Hz or 60 Hz |
| Phases | Three-phase |
| Insulation liquid | Mineral oil (FR3 natural ester optional) |
| Cooling class | ONAN / ONAN-ONAF (OFAF on request) |
| Winding material | Copper, copper / copper |
| Vector group | Dyn11 / YNd11 / YNyn0 (specify at order) |
| BIL (HV) | 200 kV BIL @ 34.5 kV class |
| Tap changer | DETC ±2 × 2.5 % standard · OLTC ±8 × 1.25 % optional |
| Temperature rise (top oil / winding) | 55 °C / 65 °C average |
| Bushings | Porcelain or composite, draw-lead or bottom-connected |
| Protection | Buchholz, pressure relief, oil/winding temperature, ground fault |

Glossary: [Liquid-filled](https://entogo.ca/glossary#liquid-filled-transformer) [kVA rating](https://entogo.ca/glossary#kva-rating) [Taps](https://entogo.ca/glossary#taps) [60 Hz vs. 50 Hz](https://entogo.ca/glossary#60-hz-vs-50-hz) [Temperature rise](https://entogo.ca/glossary#temperature-rise)

## Applications

- Utility distribution and subtransmission substations
- Industrial step-down — mining, pulp & paper, petrochemical, steel
- Solar PV and wind farm interconnection
- Data-center campus and large commercial step-down
- Railway traction and infrastructure substations

Sizing & protection

Size this transformer and its overcurrent protection before you request a quote — full-load current, primary/secondary OCPD (NEC 450.3(B) / CEC Section 26), available fault current for downstream AIC / SCCR, and a NEMA enclosure.

[Open the sizing calculator](https://entogo.ca/tools/transformer-sizing-calculator)

Payment & financing

Flexible payment and project financing is available for qualified projects — milestone-based plans, reduced upfront terms and third-party financing. Entogo is the equipment supplier, not a lender; all options are subject to credit review and a signed agreement.

[See payment options](https://entogo.ca/payment-options)

After-sales

Backed by Entogo lifecycle service — technical support, spare parts and a minimum 36-month warranty (well beyond the industry norm; up to 10 years on major power equipment, confirmed per contract). Our team responds to every request within one business day.

[After-sales support](https://entogo.ca/support) [Track an order](https://entogo.ca/support/order-status)

Power Equipment

## Related products

[![Entogo three-phase pad-mounted distribution transformer, dead-front, NEMA 3R enclosure](https://entogo.ca/_astro/Entogo-10kV-Three-Phase-Oil-Immersed-Distribution-Transformer.MmNE1ATv_Z1W8tN.webp) Power Equipment ### Three-Phase Pad-Mounted Distribution Transformer Three-phase pad-mounted distribution transformer for North-American utility, commercial and industrial service — 75–2500 kVA, 12.47–34.5 kV class primary to 480Y/277 or 208Y/120 secondary, dead-front loop/radial-feed, NEMA 3R. Designed to IEEE C57.12.34 and DOE 10 CFR 431; UL/CSA certifiable. View](https://entogo.ca/products/three-phase-pad-mounted-transformer)[![Entogo 36 kV outdoor compact unit substation for renewables and industrial sites](https://entogo.ca/_astro/Entogo-35kV-Chinese-Type-Substation.Dvb2rMnE_Z1wVTEq.webp) Power Equipment ### 36 kV Outdoor Compact Unit Substation A factory-assembled outdoor unit substation — incoming 34.5 / 35 kV switchgear, liquid-filled step-up or step-down transformer (1,000 – 10,000 kVA) and a low-voltage section in one weather-tight enclosure — for solar PV, wind, and industrial interconnection. Built to IEEE C37.121, ANSI C57.12.34 and IEC 62271-202. View](https://entogo.ca/products/outdoor-unit-substation-36kv)[![Entogo amorphous-core high-efficiency dry-type transformer](https://entogo.ca/_astro/Entogo-SCBH15-Amorphous-Alloy-Dry-Type-Transformer.CfCVUmci_Z56Pvf.webp) Power Equipment ### Amorphous-Core Dry-Type Transformer (High-Efficiency) A high-efficiency amorphous-metal-core dry-type transformer with very low no-load loss, low noise and low partial discharge — 30–2500 kVA, medium voltage to 35 kV class stepping to 480/208 V, fire-safe. Designed to UL 1562, CSA C9/C802.2 and DOE 10 CFR 431; UL/CSA certifiable. View](https://entogo.ca/products/amorphous-core-dry-type-transformer)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/oil-immersed-power-transformer-36kv/#product","url":"https://entogo.ca/products/oil-immersed-power-transformer-36kv/","name":"36 kV Oil-Immersed Power Transformer","description":"A liquid-filled (mineral oil) three-phase power transformer for substation and subtransmission duty in 34.5 / 35 / 36 kV networks, rated 2.5 to 31.5 MVA with ONAN / ONAF cooling, off-circuit or on-load tap changing and copper windings, designed to IEEE C57.12.00 / C57.12.10 and IEC 60076.","image":"https://entogo.ca/_astro/Entogo-35kV-Three-Phase-Oil-Immersed-Distribution-Transformer.BWoRk9EQ.png","category":"Transformers & Substations","additionalType":"https://en.wikipedia.org/wiki/Distribution_transformer","brand":{"@type":"Brand","name":"Entogo"},"manufacturer":{"@id":"https://entogo.ca/#organization"},"model":"2.5 – 31.5 MVA · 36 kV class","additionalProperty":[{"@type":"PropertyValue","name":"Applicable standards","value":"IEEE C57.12.00 / C57.12.10 · IEC 60076 · CSA C88"},{"@type":"PropertyValue","name":"Rated capacity","value":"2.5 – 31.5 MVA"},{"@type":"PropertyValue","name":"Highest voltage for equipment (Um)","value":"36 kV class (system 34.5 / 35 kV)"},{"@type":"PropertyValue","name":"Low-voltage winding","value":"0.4 / 4.16 / 6.6 / 12.47 / 13.8 kV (others on request)"},{"@type":"PropertyValue","name":"Frequency","value":"50 Hz or 60 Hz"},{"@type":"PropertyValue","name":"Phases","value":"Three-phase"},{"@type":"PropertyValue","name":"Insulation liquid","value":"Mineral oil (FR3 natural ester optional)"},{"@type":"PropertyValue","name":"Cooling class","value":"ONAN / ONAN-ONAF (OFAF on request)"},{"@type":"PropertyValue","name":"Winding material","value":"Copper, copper / copper"},{"@type":"PropertyValue","name":"Vector group","value":"Dyn11 / YNd11 / YNyn0 (specify at order)"},{"@type":"PropertyValue","name":"BIL (HV)","value":"200 kV BIL @ 34.5 kV class"},{"@type":"PropertyValue","name":"Tap changer","value":"DETC ±2 × 2.5 % standard · OLTC ±8 × 1.25 % optional"},{"@type":"PropertyValue","name":"Temperature rise (top oil / winding)","value":"55 °C / 65 °C average"},{"@type":"PropertyValue","name":"Bushings","value":"Porcelain or composite, draw-lead or bottom-connected"},{"@type":"PropertyValue","name":"Protection","value":"Buchholz, pressure relief, oil/winding temperature, ground fault"},{"@type":"PropertyValue","name":"Application","value":"Utility distribution and subtransmission substations"},{"@type":"PropertyValue","name":"Application","value":"Industrial step-down — mining, pulp & paper, petrochemical, steel"},{"@type":"PropertyValue","name":"Application","value":"Solar PV and wind farm interconnection"},{"@type":"PropertyValue","name":"Application","value":"Data-center campus and large commercial step-down"},{"@type":"PropertyValue","name":"Application","value":"Railway traction and infrastructure substations"},{"@type":"PropertyValue","name":"Delivery lead time","minValue":16,"maxValue":24,"unitCode":"WEE"},{"@type":"PropertyValue","name":"Warranty (minimum)","value":36,"unitCode":"MON"}],"isRelatedTo":[{"@type":"Product","name":"Three-Phase Pad-Mounted Distribution Transformer","url":"https://entogo.ca/products/three-phase-pad-mounted-transformer/"},{"@type":"Product","name":"36 kV Outdoor Compact Unit Substation","url":"https://entogo.ca/products/outdoor-unit-substation-36kv/"},{"@type":"Product","name":"Amorphous-Core Dry-Type Transformer (High-Efficiency)","url":"https://entogo.ca/products/amorphous-core-dry-type-transformer/"}],"potentialAction":{"@type":"QuoteAction","name":"Request a quote","target":"https://entogo.ca/products/transformer-quote?from=36%20kV%20Oil-Immersed%20Power%20Transformer"}}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://entogo.ca/"},{"@type":"ListItem","position":2,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":3,"name":"Transformers & Substations","item":"https://entogo.ca/products/category/transformers-substations/"},{"@type":"ListItem","position":4,"name":"36 kV Oil-Immersed Power Transformer","item":"https://entogo.ca/products/oil-immersed-power-transformer-36kv/"}]}
```

_Markdown twin of https://entogo.ca/products/oil-immersed-power-transformer-36kv/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_
