title: "Scott-Connected Transformer | Entogo"
description: "Entogo supplies Scott-connected transformers for conversion between three-phase and two-phase circuits."
url: https://entogo.ca/products/scott-connected-transformer/
lang: en
type: website
image: https://entogo.ca/_astro/scott-connected-transformer.C8DBVrLO.webp
alternates:
  en: https://entogo.ca/products/scott-connected-transformer/
  fr-CA: https://entogo.ca/fr/products/scott-connected-transformer/
  fr: https://entogo.ca/fr/products/scott-connected-transformer/
  es: https://entogo.ca/es/products/scott-connected-transformer/
  ar: https://entogo.ca/ar/products/scott-connected-transformer/
  pl: https://entogo.ca/pl/products/scott-connected-transformer/
  ro: https://entogo.ca/ro/products/scott-connected-transformer/
  ru-KZ: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-UZ: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-KG: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-TJ: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-TM: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-AZ: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-AM: https://entogo.ca/ru/products/scott-connected-transformer/
  ru-GE: https://entogo.ca/ru/products/scott-connected-transformer/
site: https://entogo.ca/
llms: https://entogo.ca/llms.txt
---

Products › Special-Purpose Transformers › Scott-Connected Transformer

Special-Purpose Transformers

# Scott-Connected Transformer

![Scott-Connected Transformer](https://entogo.ca/_astro/scott-connected-transformer.C8DBVrLO_Zvi3Tr.webp)

Representative configuration. The offered model, dimensions and interfaces are confirmed with the technical proposal.

Overview

Entogo supplies Scott-connected transformers for conversion between three-phase and two-phase circuits. Define the two output loads, 90° phase relationship, voltage ratio and operating cycle before selecting the winding design.

Entogo supplies this project equipment through manufacturing partners. Entogo Inc. in Toronto coordinates technical selection, supply scope and order support.

| Specification | Value |
| --- | --- |
| Connection | Scott T arrangement with main and teaser transformer sections |
| Output phase relation | Two output circuits in quadrature: 90° electrical displacement |
| Winding construction | Separate secondary windings; terminal identification agreed by drawing |
| Reference construction | Dry-type, naturally cooled, open construction; enclosure separately specified |
| Rated duty | Power, power factor and loading specified for each output circuit |
| Balance assessment | Three-phase input balance evaluated against both output loads |
| Frequency and insulation | Supply frequency, winding voltages and insulation coordinated per design |
| Verification | Ratio, polarity, phase relationship and agreed load/test conditions |

Reference configurations and selection criteria are shown together. The technical offer defines the matched ratings, tests and guaranteed performance for the ordered unit.

## Define both output circuits

The Scott connection uses main and teaser sections to create the required two-phase relationship. A single total-kVA value hides how the two outputs will actually be loaded. Give the power factor and operating cycle of each circuit.

Input balance depends on the output loads and connection. Where process loads vary independently, evaluate the relevant operating cases instead of assuming the three-phase supply always remains balanced.

## Applications

- Special phase conversion
- Industrial electrical systems
- Project-specific power interfaces

## Selection & project requirements

- **Does a Scott transformer simply create two ordinary single-phase supplies?**: Its defining feature is the two-phase relationship, normally 90° between outputs. The connection and load duty must match the application. It is not interchangeable with an ordinary three-phase distribution transformer or an arbitrary pair of single-phase units.
- **Will the input remain balanced with unequal output loads?**: Not automatically. The relationship between the two loads affects the three-phase input currents. Provide simultaneous and independent loading cases, power factor and the allowable unbalance for the network study.
- **Is this automatically a railway traction transformer?**: No. Scott connection describes a winding arrangement. Traction service introduces its own voltage, insulation, loading, protection and approval requirements. Identify traction duty explicitly if that is the intended application.
- **How should a Scott conversion project be specified?**: Provide a connection diagram, both output voltages and loads, frequency, phase relationship, duty cycle, insulation requirements and installation conditions. Agree terminal marking and the tests needed to verify the intended conversion before manufacture.

For Canadian and US projects, include the utility specification, service frequency and required approvals. State whether the order is for the transformer alone or an integrated equipment package.

## Discuss your equipment requirements

Send your single-line diagram, load or process data, target market and required schedule. We will identify the configuration and documents needed for a technical quotation.

## Related equipment

[![Electrical Isolation Transformer](https://entogo.ca/_astro/isolation-transformer.DSeX7yhX_Z1TxHzw.webp) Products ### Electrical Isolation Transformer Entogo supplies electrical isolation transformers with separate primary and secondary windings. Select voltage ratio, kVA, shielding, grounding and enclosure for the load; isolation duty and dry-type construction are distinct requirements. View](https://entogo.ca/products/isolation-transformer/)[![Solar Inverter-Duty Transformer](https://entogo.ca/_astro/solar-inverter-duty-transformer.CmSgUtIf_1aiy1j.webp) Products ### Solar Inverter-Duty Transformer Entogo supplies inverter-duty transformers for PV and battery-storage interconnection. Match the inverter/PCS voltage, winding arrangement, grounding, harmonics and thermal duty to the collector network and connection study. View](https://entogo.ca/products/solar-inverter-duty-transformer/)[![Electric Furnace Transformer](https://entogo.ca/_astro/electric-furnace-transformer.DhAc_6a9_uC1cB.webp) Products ### Electric Furnace Transformer Entogo supplies electric-furnace transformers for metallurgical processes. Furnace type, secondary current, voltage range, impedance, tap operation and the complete heat cycle determine the design rather than plant demand alone. View](https://entogo.ca/products/electric-furnace-transformer/)[![Representative outline drawing of an Entogo three-phase dead-front pad-mounted transformer — front and side elevations, not a photograph](https://entogo.ca/_astro/Entogo-Three-Phase-Pad-Mounted-Transformer-Outline.BEuthAyQ_ggksH.webp) Products ### Three-Phase Pad-Mounted Distribution Transformer Three-phase pad-mounted distribution transformer for North American utility, commercial and industrial service — 75–2500 kVA, 12.47–34.5 kV class primary to 480Y/277 or 208Y/120 secondary, dead-front loop/radial-feed, NEMA 3R. Designed to IEEE C57.12.34 and DOE 10 CFR 431; UL/CSA certifiable. View](https://entogo.ca/products/three-phase-pad-mounted-transformer/)

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"Product","@id":"https://entogo.ca/products/scott-connected-transformer/#product","url":"https://entogo.ca/products/scott-connected-transformer/","name":"Scott-Connected Transformer","description":"Entogo supplies Scott-connected transformers for conversion between three-phase and two-phase circuits. Define the two output loads, 90° phase relationship, voltage ratio and operating cycle before selecting the winding design.","image":"https://entogo.ca/_astro/scott-connected-transformer.C8DBVrLO.webp","potentialAction":{"@type":"QuoteAction","target":"https://entogo.ca/products/scott-connected-transformer/#quote","recipient":{"@id":"https://entogo.ca/#organization"}},"additionalProperty":[{"@type":"PropertyValue","name":"Supply model","value":"Partner-supplied project equipment"},{"@type":"PropertyValue","name":"Connection","value":"Scott T arrangement with main and teaser transformer sections"},{"@type":"PropertyValue","name":"Output phase relation","value":"Two output circuits in quadrature: 90° electrical displacement"},{"@type":"PropertyValue","name":"Winding construction","value":"Separate secondary windings; terminal identification agreed by drawing"},{"@type":"PropertyValue","name":"Reference construction","value":"Dry-type, naturally cooled, open construction; enclosure separately specified"},{"@type":"PropertyValue","name":"Rated duty","value":"Power, power factor and loading specified for each output circuit"},{"@type":"PropertyValue","name":"Balance assessment","value":"Three-phase input balance evaluated against both output loads"},{"@type":"PropertyValue","name":"Frequency and insulation","value":"Supply frequency, winding voltages and insulation coordinated per design"},{"@type":"PropertyValue","name":"Verification","value":"Ratio, polarity, phase relationship and agreed load/test conditions"}]}
```

```json
{"@context":"https://schema.org","@type":"FAQPage","mainEntity":[{"@type":"Question","name":"Does a Scott transformer simply create two ordinary single-phase supplies?","acceptedAnswer":{"@type":"Answer","text":"Its defining feature is the two-phase relationship, normally 90° between outputs. The connection and load duty must match the application. It is not interchangeable with an ordinary three-phase distribution transformer or an arbitrary pair of single-phase units."}},{"@type":"Question","name":"Will the input remain balanced with unequal output loads?","acceptedAnswer":{"@type":"Answer","text":"Not automatically. The relationship between the two loads affects the three-phase input currents. Provide simultaneous and independent loading cases, power factor and the allowable unbalance for the network study."}},{"@type":"Question","name":"Is this automatically a railway traction transformer?","acceptedAnswer":{"@type":"Answer","text":"No. Scott connection describes a winding arrangement. Traction service introduces its own voltage, insulation, loading, protection and approval requirements. Identify traction duty explicitly if that is the intended application."}},{"@type":"Question","name":"How should a Scott conversion project be specified?","acceptedAnswer":{"@type":"Answer","text":"Provide a connection diagram, both output voltages and loads, frequency, phase relationship, duty cycle, insulation requirements and installation conditions. Agree terminal marking and the tests needed to verify the intended conversion before manufacture."}}],"inLanguage":"en"}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Products","item":"https://entogo.ca/products/"},{"@type":"ListItem","position":2,"name":"Special-Purpose Transformers","item":"https://entogo.ca/products/families/special-purpose-transformers/"},{"@type":"ListItem","position":3,"name":"Scott-Connected Transformer"}],"inLanguage":"en"}
```

_Markdown twin of https://entogo.ca/products/scott-connected-transformer/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/llms.txt_