title: "Posturi compacte și prefabricate | Entogo"
description: "Entogo — Posturi compacte și prefabricate. Comparați pachetele complete cu furnizarea transformatorului individual."
url: https://entogo.ca/ro/products/families/compact-substations/
lang: ro
type: website
image: https://entogo.ca/og-cover.jpg
alternates:
  en: https://entogo.ca/products/families/compact-substations/
  fr-CA: https://entogo.ca/fr/products/families/compact-substations/
  fr: https://entogo.ca/fr/products/families/compact-substations/
  es: https://entogo.ca/es/products/families/compact-substations/
  ar: https://entogo.ca/ar/products/families/compact-substations/
  pl: https://entogo.ca/pl/products/families/compact-substations/
  ro: https://entogo.ca/ro/products/families/compact-substations/
  ru-KZ: https://entogo.ca/ru/products/families/compact-substations/
  ru-UZ: https://entogo.ca/ru/products/families/compact-substations/
  ru-KG: https://entogo.ca/ru/products/families/compact-substations/
  ru-TJ: https://entogo.ca/ru/products/families/compact-substations/
  ru-TM: https://entogo.ca/ru/products/families/compact-substations/
  ru-AZ: https://entogo.ca/ru/products/families/compact-substations/
  ru-AM: https://entogo.ca/ru/products/families/compact-substations/
  ru-GE: https://entogo.ca/ru/products/families/compact-substations/
site: https://entogo.ca/
llms: https://entogo.ca/ro/llms.txt
---

Produse › Posturi compacte și prefabricate

Entogo

# Posturi compacte și prefabricate

Comparați pachetele complete cu furnizarea transformatorului individual.

Stabiliți dacă aveți nevoie de transformator separat sau de un post complet cu celule, protecții și servicii proprii. Includeți schema monofilară, planul amplasamentului, limitele de acces și responsabilitățile de montaj pentru a delimita corect oferta.

[![Post de transformare prefabricat Entogo în anvelopă metalică albă, cu uși separate pentru compartimentele de medie și joasă tensiune și grile de ventilație](https://entogo.ca/_astro/Entogo-Prefabricated-Substation-Series.DVq0FUxf_Z1q59Nl.webp) Posturi compacte și prefabricate ### Post de transformare prefabricat MT/JT în anvelopă metalică (PTM) Post de transformare prefabricat (compact) MT/JT în anvelopă metalică (PTM), 20/0,4 kV, transformator în ulei sau uscat de până la 2500 kVA, aparataj MT 24 kV / 16 kA 1 s fără SF6, anvelopă IP43, IAC-AB conform proiectului. Conform SR EN IEC 62271-202, 62271-200 și 61439-1/-2. Valori tipice, configurare la comandă. Vedeți detalii](https://entogo.ca/ro/products/compact-secondary-unit-substation/)[![Post de transformare de exterior Entogo, clasa 36 kV, cu compartimente MT și JT în anvelopă metalică și transformator în ulei cu radiatoare și conservator](https://entogo.ca/_astro/Entogo-35kV-Chinese-Type-Substation.Dvb2rMnE_Z1wVTEq.webp) Posturi compacte și prefabricate ### Post de transformare 33–36 kV pentru surse regenerabile și industrie Post de transformare de exterior pentru surse regenerabile și industrie, 1000–10.000 kVA, MT 20 sau 33 kV (Um până la 36 kV), JT 0,4 / 0,69 / 0,8 kV, transformator în ulei ONAN, anvelopă IP54, releu de protecție și SCADA. Conform SR EN IEC 62271-202 și SR EN 60076. Valori tipice, configurare la comandă. Vedeți detalii](https://entogo.ca/ro/products/outdoor-unit-substation-36kv/)[![Post de transformare ridicător Entogo pentru parcuri fotovoltaice și BESS, în container metalic alb cu uși de acces pentru compartimente și grile de ventilație](https://entogo.ca/_astro/Entogo-New-Energy-Integrated-PV-Prefabricated-Box-Substation.BbhcGbvm_Z1ULC7s.webp) Posturi compacte și prefabricate ### Post de transformare ridicător pentru parcuri fotovoltaice și BESS Post de transformare ridicător JT/MT pentru parcuri fotovoltaice și BESS, tipic 1000–6300 kVA, 0,6–0,8 kV la invertoare și 20 kV pe partea MT (Um până la 36 kV), transformator pentru regim cu invertoare, aparataj MT fără SF6. Conform SR EN 60076 și SR EN IEC 62271-202. Valori tipice, configurare la comandă. Vedeți detalii](https://entogo.ca/ro/products/solar-storage-skid-substation/)

## Ghiduri de proiectare

[![Tablou de joasă tensiune Entogo din trei coloane: coloană de compensare a energiei reactive, coloană de plecări cu sertare debroșabile și coloană de intrare cu întreruptor automat deschis (ACB)](https://entogo.ca/_astro/Entogo-MNS-Low-Voltage-Withdrawable-Switchgear.DJOoH7XN_Z26kTQH.webp) Referință tehnică ### SR EN 61439 (SR EN IEC 61439-1/-2): formele de separare 1–4b, verificarea de proiect și Icw/Ipk pentru tabloul de joasă tensiune SR EN 61439 (azi SR EN IEC 61439-1/-2:2021, identice cu IEC 61439-1/-2:2020) cere pentru orice tablou de JT verificare de proiect (cap. 10) și verificare individuală (cap. 11). Forma de separare 1–4b se convine cu producătorul. Forme, verificări, InA, Icw, Ipk și valorile DEER ST 108: 1600 A, 35 kA/1 s, 74 kA. Vedeți detalii](https://entogo.ca/ro/insights/sr-en-iec-61439-forme-de-separare-verificare/)[![Post de transformare ridicător Entogo pentru parc fotovoltaic, în container metalic alb cu uși de acces la compartimentul de medie tensiune, la transformator și la tabloul de joasă tensiune](https://entogo.ca/_astro/Entogo-New-Energy-Integrated-PV-Prefabricated-Box-Substation.BbhcGbvm_Z1ULC7s.webp) Ghid de racordare ### Studiu de soluție parc fotovoltaic: ce date de echipament cere operatorul și cum dimensionați postul ridicător Studiul de soluție pentru un parc fotovoltaic este obligatoriu la medie tensiune peste 1 MW evacuat (Ord. ANRE 102/2015); operatorul îl transmite avizat în cel mult o lună, apoi emite ATR-ul. Ce date de echipament predați, tipurile NC RfG din România și un calcul pentru 5 MWp: 4,0 MW, 4,6 MVA, 2 × 2500 kVA. Vedeți detalii](https://entogo.ca/ro/insights/studiu-de-solutie-parc-fotovoltaic/)[![Stație de transformare de exterior cu un transformator de putere în ulei montat între pereți antifoc din beton, sub portalurile liniilor aeriene](https://entogo.ca/_astro/total-owning-cost-transformer-loss-evaluation.C6bYtPQN_z9pu1.webp) Ghid de calcul ### Pierderi transformator: calcul în kWh și lei pe an, cum se verifică și când le plătiți pe factură Pierderi transformator: ΔW = P0 × 8760 + Pk × (S/Sn)² × τ. Un transformator de 630 kVA Ecodesign Faza 2, cu vârf de 500 kVA și Tmax 4000 h, pierde circa 11.700 kWh pe an, adică circa 11.160 lei la prețul Eurostat. Cu contorul pe JT și delimitarea pe MT, operatorul adaugă aceste pierderi pe factură. Vedeți detalii](https://entogo.ca/ro/insights/calcul-pierderi-transformator/)

Pentru România, Republica Moldova sau alte piețe europene, indicați operatorul de rețea, frecvența, standardele SR EN/IEC aplicabile și documentația de recepție. Cerințele de conformitate se stabilesc pentru echipamentul și amplasamentul concret.

## Să discutăm cerințele echipamentelor

[Solicitați o ofertă](https://entogo.ca/ro/contact/)

## Explorați familiile de echipamente

Comparați echipamentele după funcție și montaj. Fișele indică conținutul livrării și datele necesare ofertării.

## Structured data (JSON-LD)

```json
{"@context":"https://schema.org","@type":"CollectionPage","@id":"https://entogo.ca/ro/products/families/compact-substations/#collection","url":"https://entogo.ca/ro/products/families/compact-substations/","name":"Posturi compacte și prefabricate","description":"Entogo — Posturi compacte și prefabricate. Comparați pachetele complete cu furnizarea transformatorului individual.","mainEntity":{"@type":"ItemList","itemListElement":[{"@type":"ListItem","position":1,"name":"Post de transformare prefabricat MT/JT în anvelopă metalică (PTM)","url":"https://entogo.ca/ro/products/compact-secondary-unit-substation/"},{"@type":"ListItem","position":2,"name":"Post de transformare 33–36 kV pentru surse regenerabile și industrie","url":"https://entogo.ca/ro/products/outdoor-unit-substation-36kv/"},{"@type":"ListItem","position":3,"name":"Post de transformare ridicător pentru parcuri fotovoltaice și BESS","url":"https://entogo.ca/ro/products/solar-storage-skid-substation/"}]},"inLanguage":"ro"}
```

```json
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Produse","item":"https://entogo.ca/ro/products/"},{"@type":"ListItem","position":2,"name":"Posturi compacte și prefabricate"}],"inLanguage":"ro"}
```

_Markdown twin of https://entogo.ca/ro/products/families/compact-substations/ — generated at build time from the same content as the HTML page. Company facts, catalogue index and contact: https://entogo.ca/ro/llms.txt_