Transformers & Substations

Three-Phase Dry-Type Distribution Transformer

15 – 2500 kVA · LV 600 V class & MV

Configure & quote

Customize your Three-Phase Dry-Type Distribution Transformer and get a quote.

Overview

A three-phase ventilated dry-type distribution transformer for indoor commercial/industrial service — 15–2500 kVA, low-voltage 600 V class (480 to 208Y/120) and medium-voltage to 35 kV class, 220 °C insulation. Designed to UL 1561/1562, CSA C9 and DOE 10 CFR 431; UL/CSA certifiable.

Entogo, a Canadian company, builds the Three-Phase Dry-Type Distribution Transformer in its own factory in China with a vertically integrated supply chain — factory-direct pricing, shipping in 16–24 weeks (within 36 weeks when the order needs new cULus/CSA certification), and a minimum 36-month manufacturer warranty backed by Entogo Inc. in Toronto.

This three-phase ventilated dry-type distribution transformer pairs DOE-compliant efficiency with the oil-free, fire-safe installation that occupied buildings and indoor electrical rooms require. Ratings span 15 to 2500 kVA at 60 Hz, in both low-voltage 600 V class configurations (for example 480 V delta to 208Y/120) and medium-voltage units with primaries to the 35 kV class.

A 220 °C insulation system with standard 150 °C rise (115 °C or 80 °C optional) gives margin for continuous loading, and K-factor windings handle the harmonic content of data-center and other non-linear loads. Copper or aluminum windings, NEMA 1 / 2 indoor or 3R outdoor enclosures, and cast-resin or VPI construction are specified per project. Designed and built to UL 1561 / 1562, NEMA and CSA C9, with UL (cULus) / CSA certification available on request.

Key features

  • Designed and built to UL 1561 (≤600 V) / UL 1562 (>600 V), NEMA and CSA C9, 60 Hz — UL (cULus) / CSA certification available on request.
  • Oil-free, fire-safe construction for indoor installation where liquid-filled units are prohibited (schools, hospitals, high-rises).
  • DOE 10 CFR 431 efficiency-compliant; 220 °C insulation system with standard 150 °C rise (115 °C / 80 °C optional).
  • Low-voltage 600 V class (e.g., 480 Δ to 208Y/120) and medium-voltage configurations to 35 kV class.
  • K-factor windings available for harmonic / non-linear loads; copper or aluminum windings.
  • NEMA 1 / 2 indoor or 3R outdoor enclosure; configuration specified per project.

Custom-engineered · built to order

Get a quote

Lead time

16–24 weeks

Order now for estimated delivery Mar 2027 – May 2027.

Certification and testing may extend this, depending on the applicable standard and scope.

FAQ

Common questions

When should I choose a dry-type transformer instead of a liquid-filled one?
Dry-type units are oil-free and fire-safe, so they are specified for indoor and occupied-building installations — schools, hospitals, high-rises, data centers — where liquid-filled transformers are restricted by code or preference.
What voltages and ratings are available?
15–2500 kVA, 60 Hz. Low-voltage 600 V class units (e.g., 480 V delta to 208Y/120 or 480Y/277) and medium-voltage units with primaries to the 35 kV class are built to order.
Are these DOE-compliant and UL certifiable?
Yes. They are designed to UL 1561 / 1562, NEMA standards and DOE 10 CFR 431 efficiency requirements. UL (cULus) / CSA certification is available on request, with certified units shipping within 36 weeks.