Switchgear & Circuit Breakers
Choose switchgear by voltage, switching function and assembly construction.
Separate a complete switchgear assembly from a standalone outdoor circuit breaker. Specify system voltage, continuous and fault current, protection, control supply, service access and insulation medium. Medium-voltage panels, low-voltage boards and outdoor breakers are coordinated equipment, each with its own selection criteria.
Switchgear & Circuit Breakers
Dead Tank Circuit Breaker
Entogo supplies outdoor dead-tank circuit breakers for substation switching and protection. A 72.5 kV SF6 configuration is a reference enquiry point; continuous current, breaking duty, insulation and site conditions are specified together.
View
Switchgear & Circuit Breakers
Metal-Clad Switchgear (Drawout MV)
Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable.
View
Switchgear & Circuit Breakers
Metal-Enclosed Load-Interrupter Switchgear
Metal-enclosed load-interrupter switchgear for 15 / 27 / 38 kV class medium-voltage systems, 60 Hz — fixed-mounted load-break switches with power-fuse protection in a compact steel enclosure, for compact substations, primary service entrance and MV isolation. Designed to ANSI/IEEE C37.20.3; UL / CSA certifiable.
View
Switchgear & Circuit Breakers
Pad-Mounted Switchgear (Ring Main Unit)
Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable.
View
Switchgear & Circuit Breakers
Gas-Insulated Switchgear (GIS) — Eco-Gas / SF6-Free
Compact gas-insulated switchgear (GIS) using vacuum interrupters and an eco-friendly (SF6-free) insulating gas at near-zero gauge pressure — for space-constrained 15 / 27 / 38 kV class medium-voltage distribution, 60 Hz, with built-in online monitoring and SCADA. Designed to IEEE C37.20.9; UL / CSA certifiable.
View
Switchgear & Circuit Breakers
Modular Low-Voltage Switchgear / MCC
Modular drawer-type low-voltage switchgear and motor control center for ≤600 V, 60 Hz three-phase systems — standardized, mechanically interlocked withdrawable drawers up to 5000 A and 100 kAIC. Designed to UL 1558 and UL 845; UL/CSA certifiable.
View
Switchgear & Circuit Breakers
Low-Voltage Drawout Switchgear
Low-voltage drawout (withdrawable) switchgear for ≤600 V, 60 Hz distribution, motor control and power-factor correction — up to 5000 A and 100 kAIC, with drawout power circuit breakers, for data centers and industry. Designed to UL 1558/ANSI C37.20.1; UL/CSA certifiable.
View
Switchgear & Circuit Breakers
Low-Voltage Switchboard (UL 891)
A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable.
View
Switchgear & Circuit Breakers
Low-Voltage Switchgear & Motor Control Center
A combined low-voltage switchgear and motor control center for ≤600 V, 60 Hz systems — a power-distribution section with drawout motor-control units for distribution, motor control and lighting up to 3150 A. Designed to UL 1558 and UL 845; UL/CSA certifiable.
View
Design references
Power & Distribution
Available fault current and equipment short-circuit ratings: what to calculate and specify
Available fault current is the maximum current a bolted short circuit can push through a system at a point. Every breaker, switchboard, and control panel needs a short-circuit current rating at least equal to it, and non-dwelling service equipment must be field-marked with the value under NEC 110.24.
View
Power & Distribution
Metal-clad vs. metal-enclosed switchgear: how to choose
Metal-clad switchgear uses drawout breakers and grounded metal barriers between every compartment; metal-enclosed interrupter switchgear is simpler and built for lower fault duty. Here is how North American buyers match construction class, voltage, and fault duty to the application.
View
Power & Distribution
Gas-insulated vs. air-insulated switchgear: how to choose
Gas-insulated switchgear seals live parts in gas for a compact, low-maintenance lineup; air-insulated switchgear stays larger but fully serviceable and gas-free. The right choice turns on footprint, environment, voltage class, and tightening SF6 rules.
View
For Canadian and US projects, include the utility specification, service frequency and required approvals. State whether the order is for the transformer alone or an integrated equipment package.
Discuss your equipment requirements
Browse equipment families
Compare equipment by function and installation. Product pages identify the available scope and the information needed for a quotation.