Power Transformers
Separate distribution-level equipment from high-voltage and inverter-duty applications.
Select the transformer against the network study: voltage ratio, MVA, impedance, insulation level, tap regulation and cooling. High-voltage substation duty and inverter duty add distinct requirements. A voltage class alone does not define the transformer or the scope of supply.
Power Transformers
36 kV Oil-Immersed Power Transformer
A liquid-filled (mineral oil) three-phase power transformer for substation and subtransmission duty in 34.5 / 35 / 36 kV networks, rated 2.5 to 31.5 MVA with ONAN / ONAF cooling, off-circuit or on-load tap changing and copper windings, designed to IEEE C57.12.00 / C57.12.10 and IEC 60076.
View
Power Transformers
High-Voltage Power Transformer
Entogo supplies high-voltage power transformers for substations and industrial networks. The design brief covers MVA, voltage ratio, insulation coordination, impedance, tap regulation, cooling and transport limits.
View
Power Transformers
Solar Inverter-Duty Transformer
Entogo supplies inverter-duty transformers for PV and battery-storage interconnection. Match the inverter/PCS voltage, winding arrangement, grounding, harmonics and thermal duty to the collector network and connection study.
View
Design references
Power & Distribution
Solidly grounded, resistance-grounded, or ungrounded? Choosing a power system grounding scheme
Most North American facilities are solidly grounded, but resistance grounding can keep a plant running through a first ground fault. How to choose among solidly grounded, high-resistance grounded, and ungrounded systems, and what each requires under the NEC and IEEE 142.
View
Power & Distribution
What transformer impedance should you specify? How %Z shapes fault current and voltage drop
Transformer percent impedance (%Z) sets how much fault current the secondary can deliver and how far voltage sags under load. Lower %Z means higher available fault current and better regulation; higher %Z limits fault duty but drops more voltage. Here is how to choose it and what to specify.
View
Renewable Grid Connection
Interconnecting solar and storage to the grid: what IEEE 1547-2018 requires
Connecting solar or battery storage to the North American grid means meeting IEEE 1547-2018 for DER behavior, using a UL 1741 SB certified inverter, and passing a utility interconnection review that scales from a fast-track screen to a full study. Here is how the pieces fit.
View
For Canadian and US projects, include the utility specification, service frequency and required approvals. State whether the order is for the transformer alone or an integrated equipment package.
Discuss your equipment requirements