Switchgear & Distribution

Pad-Mounted Sectionalizing / Junction Cabinet

15 / 25 kV class · 200 / 600 A

Overview

A dead-front pad-mounted sectionalizing and junction cabinet for underground medium-voltage cable networks — 15/25 kV class, 200/600 A, 2- to 4-way, with separable elbow connections in a tamper-resistant NEMA 3R enclosure. Designed to ANSI C57.12.28 and IEEE 386; UL/CSA certifiable.

This pad-mounted sectionalizing and junction cabinet is a dead-front building block for underground medium-voltage cable networks. It lets crews sectionalize a feeder, tap laterals and join cables at one tamper-resistant cabinet — keeping cable runs clear and avoiding the large-span crossovers of a bare junction. It serves 15 / 25 kV class systems at 60 Hz, with 200 A loadbreak or 600 A deadbreak separable elbow connections (IEEE 386) on bushing wells, in 2- to 4-way arrangements.

The NEMA 3R enclosure in ANSI 70 green is offered in mild or stainless steel for coastal and harsh environments. Designed and built to ANSI C57.12.28 enclosure integrity and RUS-approvable for utility undergrounding, grid-modernization and campus cable networks, with UL / CSA certification available on request.

Key features

  • Dead-front pad-mounted cabinet for sectionalizing, tapping and joining underground medium-voltage cables without large-span cable crossovers.
  • Separable loadbreak (200 A) or deadbreak (600 A) elbow connections per IEEE 386, on bushing wells / inserts.
  • Designed and built to ANSI C57.12.28 enclosure integrity and RUS-approvable, 60 Hz — UL / CSA certification available on request.
  • Tamper-resistant NEMA 3R enclosure, ANSI 70 green; stainless steel for coastal / harsh sites.
  • 2- to 4-way configurations for compact, clearly arranged underground cable branching.

FAQ

Common questions

What is a sectionalizing / junction cabinet used for?
It is a dead-front pad-mounted cabinet that lets crews sectionalize, tap and join underground medium-voltage cables at a common point — isolating sections of a feeder for maintenance and connecting laterals without large-span cable crossovers.
What connection types and ratings are available?
15 / 25 kV class, with 200 A loadbreak or 600 A deadbreak separable elbow connections per IEEE 386, in 2- to 4-way configurations, 60 Hz. Mild or stainless steel enclosure.
Which standards apply?
Designed to ANSI C57.12.28 (pad-mounted enclosure integrity) with IEEE 386 separable connectors, and is RUS-approvable for utility use. UL / CSA certification is available on request.

Request a quote