Distribution

Switchgear & Distribution

Medium- and low-voltage switchgear, pad-mounted gear and switchboards designed to ANSI/IEEE C37 and UL for safe, reliable North-American distribution.

Entogo metal-clad medium-voltage switchgear with drawout vacuum circuit breakers

Distribution

Metal-Clad Switchgear (Drawout MV)

Metal-clad medium-voltage switchgear with drawout vacuum circuit breakers for 5/15/27/38 kV class systems, 60 Hz — compartmentalized, insulated-bus construction up to 4000 A and 50 kA, with optional arc-resistant rating. Designed to ANSI/IEEE C37.20.2; UL/CSA certifiable.

View

Entogo dead-front low-voltage switchboard, UL 891 type

Distribution

Low-Voltage Switchboard (UL 891)

A dead-front low-voltage switchboard for ≤ 600 V, 60 Hz service-entrance and distribution — up to 6000 A and 200 kA, with group-mounted molded-case or insulated-case breakers, for commercial, institutional and industrial buildings. Designed to UL 891; UL (cULus) / CSA certifiable.

View

Entogo pad-mounted ring main unit load-break switchgear, dead-front

Distribution

Pad-Mounted Switchgear (Ring Main Unit)

Pad-mounted load-break switchgear (ring main unit) for underground medium-voltage distribution — 15/25/38 kV class, 200/600 A, dead-front, with SF6 or SF6-free fault-interrupting ways for utility loops, campuses and data centers, 60 Hz. Designed to IEC 62271-200 and ANSI C57.12.28; UL/CSA certifiable.

View

Entogo metal-enclosed load-interrupter medium-voltage switchgear

Distribution

Metal-Enclosed Load-Interrupter Switchgear

Metal-enclosed load-interrupter switchgear for 15 / 27 / 38 kV class medium-voltage systems, 60 Hz — fixed-mounted load-break switches with power-fuse protection in a compact steel enclosure, for compact substations, primary service entrance and MV isolation. Designed to ANSI/IEEE C37.20.3; UL / CSA certifiable.

View

Entogo eco-gas SF6-free gas-insulated medium-voltage switchgear (GIS)

Distribution

Gas-Insulated Switchgear (GIS) — Eco-Gas / SF6-Free

Compact gas-insulated switchgear (GIS) using vacuum interrupters and an eco-friendly (SF6-free) insulating gas at near-zero gauge pressure — for space- constrained 15 / 27 / 38 kV class medium-voltage distribution, 60 Hz, with built-in online monitoring and SCADA. Designed to IEEE C37.20.9; UL / CSA certifiable.

View

Entogo smart pad-mounted switchgear with integrated metering and protection

Distribution

Smart Pad-Mounted Switchgear (Integrated RMU)

A smart pad-mounted ring main unit integrating primary load-break switchgear with secondary intelligence — instrument transformers, revenue metering, microprocessor protection, fault recording and SCADA — in one 15/25 kV class, 60 Hz unit. Designed to IEC 62271-200 and IEEE C37.74; UL/CSA certifiable.

View

Entogo low-voltage drawout (withdrawable) switchgear

Distribution

Low-Voltage Drawout Switchgear

Low-voltage drawout (withdrawable) switchgear for ≤600 V, 60 Hz distribution, motor control and power-factor correction — up to 5000 A and 100 kAIC, with drawout power circuit breakers, for data centers and industry. Designed to UL 1558/ANSI C37.20.1; UL/CSA certifiable.

View

Entogo low-voltage switchgear and motor control center

Distribution

Low-Voltage Switchgear & Motor Control Center

A combined low-voltage switchgear and motor control center for ≤600 V, 60 Hz systems — a power-distribution section with drawout motor-control units for distribution, motor control and lighting up to 3150 A. Designed to UL 1558 and UL 845; UL/CSA certifiable.

View

Entogo modular drawer-type low-voltage switchgear and motor control center

Distribution

Modular Low-Voltage Switchgear / MCC

Modular drawer-type low-voltage switchgear and motor control center for ≤600 V, 60 Hz three-phase systems — standardized, mechanically interlocked withdrawable drawers up to 5000 A and 100 kAIC. Designed to UL 1558 and UL 845; UL/CSA certifiable.

View

Entogo low-voltage distribution switchboard and panelboard

Distribution

Distribution Switchboard / Panelboard

A low-voltage distribution switchboard / panelboard for ≤600 V, 60 Hz power and lighting distribution — wall- or floor-mounted, with main and branch molded-case breakers, metering and SCCR to 100 kAIC. Designed to UL 67 (panelboard) and UL 891 (switchboard); UL/CSA certifiable.

View

Entogo automatic power-factor-correction capacitor bank

Distribution

Automatic Power-Factor-Correction Capacitor Bank

An automatic power-factor-correction (PFC) capacitor bank for 480 V, 60 Hz systems — stepped, controller-switched kVAR with detuned harmonic-filter reactors to raise power factor, cut demand charges and free transformer capacity. Designed to UL 810, IEEE 18 and NEMA CP-1; UL/CSA certifiable.

View

Entogo pad-mounted sectionalizing and cable junction cabinet, dead-front

Distribution

Pad-Mounted Sectionalizing / Junction Cabinet

A dead-front pad-mounted sectionalizing and junction cabinet for underground medium-voltage cable networks — 15/25 kV class, 200/600 A, 2- to 4-way, with separable elbow connections in a tamper-resistant NEMA 3R enclosure. Designed to ANSI C57.12.28 and IEEE 386; UL/CSA certifiable.

View

Entogo low-voltage secondary pedestal and cable junction cabinet

Distribution

Secondary Pedestal / Cable Junction Cabinet

A low-voltage secondary pedestal / cable junction cabinet for underground residential and commercial distribution (URD) — taps, branches and joins ≤ 600 V secondary cables between transformers, switchgear and services in a weatherproof NEMA 3R enclosure, 60 Hz. Designed to UL 50 / UL 50E; UL (cULus) / CSA certifiable.

View

Entogo CT metering and low-voltage distribution pedestal cabinet

Distribution

CT Metering & Distribution Cabinet (Pedestal)

A combined CT-metering and low-voltage distribution cabinet for utility and tenant service points — current-transformer metering, outgoing breakers and optional power-factor correction in one outdoor NEMA 3R pedestal, ≤600 V, 60 Hz. Designed to UL 414, UL 50/50E and UL 891; UL/CSA certifiable.

View

Entogo meter socket and CT metering enclosure, stainless steel

Distribution

Meter Socket / CT Metering Enclosure

Meter sockets and current-transformer (CT) metering enclosures for residential, commercial and utility service — 200–1200 A, ringless or ring-type, in 304/201 stainless or galvanized steel, NEMA 3R/4X. Designed to UL 414, UL 50/50E and ANSI C12.7; UL/CSA certifiable.

View

Entogo HLX new-energy AC/DC combiner box for photovoltaic systems

Distribution

HLX New-Energy AC/DC Combiner Box

The HLX combiner box for photovoltaic systems — the DC version consolidates up to 24 PV string inputs with per-string fuses, surge arresters and breakers; the AC version links string inverters to AC distribution at up to 690 V, IP65 for outdoor use.

View

Entogo BWX new-energy grid-connection box

Distribution

BWX New-Energy Grid-Connection Box

The BWX grid-connection box connects photovoltaic string inverters to the grid, with dedicated PV grid-connection circuit breakers, pull-ring isolators and secondary surge protection in an IP65 enclosure for outdoor use.

View

Entogo BWG new-energy grid-connection cabinet

Distribution

BWG New-Energy Grid-Connection Cabinet

The BWG grid-connection cabinet sits between PV inverters (or an AC combiner box) and the grid in high-power photovoltaic plants, providing under/over- voltage, surge, overcurrent and grid-isolation protection with multi-function metering and anti-islanding support.

View